Product Details:
Also Provides | Electrical Consultants |
Usage/Application | AS PER CLIENT |
Brand | As per client requirement |
Mode Of Service | As per client requirement |
Single Line or Key Line diagrams are one of the first sets of documents that are prepared at the beginning of every project. They define all the necessary primary equipment ratings, such as the short circuit and nominal current ratings of circuit all the breakers, CT & VSingle Line or Key Line diagrams are one of the first sets of documents that are prepared at the beginning of every project. They define all the necessary primary equipment ratings, such as the short circuit and nominal current ratings of circuit all the breakers, CT & VT ratings, as well as arrangement of the primary equipment. Our engineers can prepare Single Line or Key Line diagrams quickly, efficiently and can verify them with the original equipment manufacturer specifications.
T ratings, as well as arrangement of the primary equipment. Our engineers can prepare Single Line or Key Line diagrams quickly, efficiently and can verify them with the original equipment manufacturer specifications.
Product Details:
Also Provides | As per Client requirement |
Grounding network of any station is as good as the ground grid that was installed prior to the installation of the primary equipment and construction of the buildings. We can provide grounding grids for below and above grounding of primary and secondary equipment with installation details and calculations proving the integrity of the grid design.
Today we have more and more equipment that is sensitive to voltage variations or surges. Therefore lighting protection standards have been updated in order to provide more details as to what must be protected and to what degree, especially the equipment that is installed inside the buildings.
Overall site layouts can provide a plethora of crucial information with regards to the primary equipment dimensions, overall building dimensions, general building layouts and overall site dimensions .We can build substation layout adhering to all international and national standards like IEC /IS .
Product Details:
Minimum Order Quantity | 1 Unit |
Cable Type | yes |
Service Location | All over world |
Additional Information:
Product Details:
Industry Type | Oil, Gas, Petrochemical |
Usage/Application | For underground tanks and pipelines |
Cathode Protection Type | Galvanic, Impressed Current Systems |
Product Details:
Material | As per client requirements |
Usage/Application | Oil and Gas,Power sector |
We can supply power cable routing designs with adequate power cable supports from 0.4kV to 400kV power cables for any station.
Grouping and organizing low voltage control cables can be a daunting task, especially in open terminal substations. However we can provide detailed cable tray designs and infill reports. These layouts can be used with the low voltage cable schedules to determine the exact cable lengths and cable routes.
Product Details:
Project Duration | AS PER CLIENT REQUIREMENT |
We can perform detailed study on ETAP :
Short Circuit calculation Load Flow Study Motor Starting (Dynamic & static) Transient Stability Harmonic Ground Grid design & Verification Protection System Coordination & Selectivity Relay Co-ordination Study Capacitor Bank selection and sizing Cable Sizing using CYMCAP |
Product Details:
Quantity Per Pack | as per client |
Packaging Type | as per client |
Power | as per client |
Finishing | as per client |
Frequency | as per client |
Product Details:
Also Provides | As per client requirment |
Control system is an integral part of substations secondary equipment. Ideally it must provide an overview of the status of the system, whether from a local or remote point of view, while giving the operational engineers full control over the substations primary equipment. It must also be designed to provide several safety measures that will prevent operation of the primary equipment and potentially damage the installed equipment.